GLGridlinks SolutionsRequest a Quote

Quality & Evidence

Every result traceable from policy to proof

Our operating system is built so that each test result can be traced back to the procedure, limit and instrument behind it — and selected evidence is shared openly with clients.

Integrated governance framework

One management system, structured around international standards, from board-level governance down to project delivery and protection.

Governance

Governance

ISO 37000

Governance of organisations

Strategy

Direction

Objectives and QPPOs

Risk

ISO 31000

Risk management

Compliance

ISO 37301

Compliance management

Delivery system

Quality

ISO 9001

Quality management

Health & Safety

ISO 45001

OH&S management

Environment

ISO 14001

Environmental management

Asset

ISO 55001

Asset management

Energy

ISO 50001

Energy management

Project Delivery

ISO 21502

Project management

Information Security

ISO/IEC 27001

Information security management

Business Continuity

ISO 22301

Resilience and recovery

Anti-Bribery

ISO 37001

Integrity in procurement

Standards shown are the reference framework our management system is aligned to. Certification status will be listed separately once confirmed.

The ten-tier chain

  1. 01

    Policy — What we commit to

    Zero-defect energisation, safe work and compliance with AS, IEC and client standards.

  2. 02

    Process — How work flows

    Defined lifecycles such as GIS erection, testing and commissioning.

  3. 03

    Procedure — Step-by-step method

    Controlled procedures and inspection & test plans (ITPs) for each activity.

  4. 04

    Control — Hold & witness points

    Checkpoints that must be cleared before work proceeds.

  5. 05

    Measurement — Objective data

    Recorded values, e.g. SF6 dew point, PD level, contact resistance, trip times.

  6. 06

    Threshold — Pass / fail limits

    Standard limits plus tighter internal control limits to catch drift early.

  7. 07

    Evidence — Proof on record

    Instrument exports, calibrated serials, time-stamped and tamper-evident records.

  8. 08

    Corrective Action — When limits are missed

    Containment, root cause, fix and re-test before release.

  9. 09

    Management Review — Looking at the trends

    Periodic review of defect rates, capability and recurring causes.

  10. 10

    Continual Improvement — Closing the loop

    Procedures, limits and suppliers updated from what the data shows.

Quantitatively managed

Aligned to CMMI Level 4 practice: critical parameters are tracked against statistical control limits, so drift is spotted before it becomes a non-conformance. Capability is reviewed for each repeated test type.

Internal by design, shared by choice

Full records stay in our controlled system. Client-safe, anonymised evidence is published where it helps asset owners and EPCs verify our work.

Published performance objectives

Every core process has a quality and process-performance objective. A selection is published here.

ProcessMeasureObjectiveStatus
RFQFirst engineering response≤ 1 business dayBaseline being established
TestingFirst-pass acceptance≥ 98%Baseline being established
CalibrationIn-date equipment100%Baseline being established
WebsiteTechnical-content accuracy100% approvedBaseline being established
WebsiteBroken links0 criticalBaseline being established
WebsiteCore Web VitalsPassingBaseline being established
WebsiteAccessibility criticals0Baseline being established
WebsiteAvailability≥ 99.9%Baseline being established

What we surface publicly

Formal certifications and appraisal results will be listed here once confirmed.

Have a specification or scope ready?

Send us voltage class, equipment type and project phase — we respond within one business day.