Engineering procurement

Select equipment by specification, not by catalogue

Start from voltage, fault level and application. We return a technical compliance matrix, not a shopping cart.

9 of 9 categories match

132 kV+ GIS & HV Panels

Transmission & sub-transmission substations, 66–500 kV

Voltage
72.5 / 145 / 245 / 300 / 362 / 550 kV rated (Um)
Current
1250 – 5000 A busbar and feeder
Fault rating
31.5 / 40 / 50 / 63 kA, 1 s or 3 s
Specification parameters →

MV / EHV Panels

Zone substation and primary distribution switchboards

Voltage
7.2 / 12 / 24 / 36 kV rated
Current
630 – 4000 A
Fault rating
16 / 20 / 25 / 31.5 / 40 kA, 3 s
Specification parameters →

LV & ELV Panels

Main switchboards, DBs and MCCs, 240 / 415 V

Voltage
240 V single-phase / 415 V three-phase
Current
63 – 6300 A
Fault rating
Icw 10 – 100 kA, 1 s
Specification parameters →

Cable Sockets & End Terminations

MV–EHV cable terminations, joints and lugs

Voltage
12 – 362 kV Um
Current
Matched to conductor size (up to 2500 mm² Cu/Al)
Fault rating
Matched to cable screen fault rating
Specification parameters →

Smart Meters & MCBs

Revenue metering and final-circuit protection

Voltage
240 / 415 V
Current
6 – 125 A (MCB/RCBO); CT-connected meters
Fault rating
6 / 10 / 15 kA breaking capacity
Specification parameters →

Control & Protection Panels

Substation protection, control & automation (PAC)

Voltage
Serving 11 – 500 kV bays; 110/125 V DC auxiliary
Current
1 A / 5 A CT secondaries
Fault rating
Per CT/VT burden and accuracy class
Specification parameters →

FACTS & Reactive Compensation

Voltage support, power factor and harmonic control

Voltage
11 – 330 kV connection (via coupling transformer)
Current
Per Mvar rating
Fault rating
Per connection point fault level and SCR
Specification parameters →

Relays & Power Quality Meters

Protection relays and Class A power quality monitoring

Voltage
Applied at LV – EHV via CT/VT
Current
1 A / 5 A nominal inputs
Fault rating
Thermal withstand per IEC 60255-27
Specification parameters →

Solar, BESS & PCS

Utility-scale BESS, PCS and solar inverters for grid connection

Voltage
1500 V DC; 33 kV MV collection; 66 – 330 kV connection
Current
Per PCS block rating
Fault rating
Fault ride-through per NER S5.2.5.5; collection fault level per study
Specification parameters →

Have a specification or scope ready?

Send us voltage class, equipment type and project phase — we respond within one business day.