GridLinksRequest a Quote

Service · Design Management

Design Management & Owner's Engineer — Multi-Discipline Substation Packages

Owner's engineer and design management across multi-discipline substation packages.

The engineering problem

Large substation packages involve many designers, vendors and reviewers. Without firm interface control, RFIs pile up and non-compliances reach site.

Capability

  • Design review against client standards
  • Interface control across disciplines and vendors
  • Technical query and RFI management
  • Vendor document review
  • Compliance tracking

Voltage / application

11 kV22 kV33 kV66 kV132 kV220 kV275 kV330 kV500 kV

Inputs — client data required

  • Contract and technical specifications
  • Design programme
  • Vendor document schedules
  • Client standards

Deliverables

  • Design review comment sheets
  • Interface register
  • RFI and TQ register
  • Compliance matrix
  • Design status reports

Engineering software

  • Common data environment (CDE) used on the project

Methodology

  1. Stage 1

    Mobilise

    Set up registers and review process.

  2. Stage 2

    Review

    Review submissions at each gate.

  3. Stage 3

    Control

    Track interfaces, RFIs and compliance.

  4. Stage 4

    Close-out

    Confirm all comments closed.

Design gates

30%

Concept review

60%

Design development review

90%

Pre-IFC review

IFC

Compliance confirmed

Verification — checker / approver model

  1. 1.Originator prepares the deliverable
  2. 2.Independent checker verifies calculations, drawings and assumptions
  3. 3.Discipline lead approves for issue
  4. 4.RPEQ / chartered engineer sign-off where required by jurisdiction or client

Standards

AS 2067IEC 61936-1ISO 21502Client specifications

Utility requirements

  • DNSP connection and design standards (e.g. Ausgrid, Endeavour, Essential, Energex/Ergon, Powercor, SA Power Networks)
  • TNSP requirements (e.g. Transgrid, Powerlink, AusNet, ElectraNet, TasNetworks)
  • AEMO / National Electricity Rules Chapter 5 connection obligations
  • Network operator access, switching and permit-to-work rules

Quality controls

  • Review checklists
  • Comment close-out tracking
  • Document control

HSE considerations

  • SiD process oversight
  • Hazard register maintained across designers

Cyber controls

  • CDE access controls
  • Review of OT security design where in scope

Sustainability

  • Material efficiency and reduced site rework
  • Waste segregation and recycling on site
  • Embodied-carbon awareness in equipment selection

Asset lifecycle — ISO 55001 perspective

  • Design decisions recorded against asset life-cycle cost (ISO 55001)
  • Asset data and as-built records handed over in client asset-register format
  • Maintainability and spares strategy considered at design stage

Interfaces

  • All design disciplines
  • Vendors and OEMs
  • Client and network operator

Typical programme

Mobilisation1–2 weeks
Ongoing reviewFor the design phase

Indicative only — actual programme depends on scope, approvals and outage windows.

Case studies

Technical FAQs

Can you act as owner's engineer?

Yes, on behalf of asset owners and developers.

Capability datasheet

The Design Management capability datasheet (PDF) is available on request.

Request datasheet

Discuss your project

Share voltage, scope and programme and an engineer will be in touch.

Discuss your project